XP-Series

XP-3020 XP-3030 XP-3050 XP-30100

 

 

* 1㎷/1㎃ Resolution (Control & Display)
* Pattern Edition - 100EA (Voltage, Current,
  Slop time, Delay time, Cycle)
* User Memory Store/Recall
  - 10EA (Voltage, Current, OVP, OCP)
* Easy to control Voltage & Current with Jog Shuttle.
* Voltage, Current Soft Calibration
* High Quality VFD Display
* Interface (SCPI) : Built-in RS-232C
                             GPIB (Option)
* Over Voltage Protection Circuit (O.V.P)
* Over Current Protection Circuit (O.C.P)
* Last Power (Update, Remain, Safety)
* Constant Voltage (C.V), Constant Current (C.C) Mode
* Windows OS Operation
* Built-in Remote Sensing.
* Output Voltage : 0~1500V
* Output Current : 0~500A

 
 
XP-3020
XP-3030
XP-3050
XP-30100
OUTPUT VOLTAGE
0~30V
0-30V
0~30V
0~30V
OUTPUT CURRENT
0~20A
0~30A
0~50A
0~100A
MAX. OUTPUT POWER
600W
900W
1500W
3000W
LINE REGULATION
Less than 0.03% for power source voltage change of ±10%
LOAD REGULATION
Less than 0.03% for load variation of 0 to 100%
RIPPLE & NOISE
≤0.01%mVrms
≤0.02%mVrms
≤0.03%mVrms
≤0.04%mVrms
PROGRAMMING
ACCURACY
VOLTAGE
<0.05%+20㎷
CURRENT
<0.2%+5㎃
READBACK
ACCURACY
VOLTAGE
<0.1%+20㎷
CURRENT
<0.15%+15㎃
RESOLUTION
PROGRAM
<50㎶ / 50㎂
<50㎷ / 100㎂
READBACK
<50㎶ / 50㎂
<50㎷ / 100㎂
METER
<1㎷+1㎃
1㎷/10㎃
INSULATION
Between chassis and Output : more than 10㏁ at DC500V
Between chassis and AC plug : more than 50㏁ at DC500V
COMPENSATION/PROTECTION
Over Voltage Protection, Over Current Protection
AMBIENT TEMPERATURE RANGE
5℃~40℃
POWER SOURCE
AC 220V, 230V 50/60㎐ (Option: AC 100V, 110V)
REMOTE INTERFACE
RS-232C/GPIB(Option)
WEIGHT(Kg)
25Kg