200MHz(200MS/s) 디지털오실로스코프(Digital Oscilloscope) : 모델 DL 1640/1640L

  • 4 channels, 200 MS/s
  • 200 MHz analog bandwidth
  • Maximum memory length: 32 MW (DL1640L) and 8 MW (DL1640)
  • 6.4-inch wide-angle-view TFT color liquid crystal display
  • Compact and lightweight (approx. 3.9 kg)
  • A4 size or smaller footprint
  • Internal storage media (select PC card, Zip? drive, or floppy drive)
  • USB compliant (optional)
  • Ethernet connectivity (optional)
  • Real-time digital filtering
▶ 장비사양(SPECIFICATIONS)
▷ Basic Specifications
Input Channels 4
Input Coupling 1 MΩ AC, 1 MΩ DC, GND
Input Impedance 1 MΩ ±1.0%, 28 pF at 1 MHz
Sensitivity 2 mV/div to 10 V/div (in steps of 1, 2, or 5)
Maximum Input Voltage 300 V DC or 300 Vrms CAT I, 424 Vpeak
Maximum DC Offset Range 2 mV/div to 50 mV/div: ±1 V (with 1:1 probe attenuation ratio)
100 mV/div to 500 mV/div: ±10 V
1 V/div to 5 V/div: ±100 V
10 V/div: ±50 V
DC Accuracy 10 mV/div to 10 V/div: ±1.5% of 8 div + offset voltage accuracy
2 mV/div to 5 mV/div: ±2.0% of 8 div + offset voltage accuracy
Offset Voltage Accuracy 2 mV/div to 50 mV/div: ±(1% of setting + 0.2 mV)
100 mV/div to 500 mV/div: ±(1% of setting + 2 mV)
1 V/div to 10 V/div: ±(1% of setting + 20 mV)
Probe Attenuation Ratio 1:1, 10:1, 100:1, 1000:1
Current probe (700937, 701930)
Frequency Characteristics 10 mV/div to 10 V/div: DC to 200 MHz
2 mV/div to 5 mV/div: DC to 80 MHz
(using 700960; specified at probe tip)
Vertical Resolution 8 bits (24 LSB/div)
High resolution mode: Maximum 13 bits
Maximum Sampling Rate During real-time sampling: 200 MS/s
During equivalent time sampling: 50 GS/s
Maximum Record Length 701610:
  • 8 MW/ch (in single trigger mode)
  • 1 MW/ch (in other modes) 701620:
  • 32 MW/ch (in single trigger mode)
  • 4 MW/ch (in other modes)
  • Sweep Time 2 ns/div to 50 s/div (with 10 kW or greater record length)
    2 ns/div to 5 s/div (with 1 kW record length)
    Time Base Accuracy ±0.005%
    External Clock Input Input frequency range 40 Hz to 5 MHz (continuous clock only)
    ▷ Trigger
    Trigger Modes Auto, Auto Level, Normal, Single, Single (N)
    Trigger Sources CH1 to CH4, LINE, EXT
    Trigger Types Edge, A / B(N), A delay B, OR, pattern, pulse width, TV (NTSC, PAL, SECAM, 1080/60p, 1080/60i, 1080/24p, 1080/50i, 1080/25p, 1080/24sF, 720/60p, 480/60p)
    ▷ Display
    Display 6.4-inch TFT color liquid crystal display
    Screen Updating Rate Up to 60 times per second during 100 kW all-points display
    Up to 30 times per second during 1 MW all-points display
    The LCD may contain some pixels that are always or always on. In addition, brightness may vary due the characteristics of the LCD, but this is not an indication of any problem with the display.
    ▷ Functions
    Vertical Horizontal Functions
    Input Filter 20 MHz band limits can be set separately on CH1 through CH4.
    Input Digital Filter 10 kHz to 1.28 MHz band limits can be set separately on CH1 through CH4.
    Roll Mode 50 ms/div to 50 s/div (during auto, auto level, and single trigger modes)
    Note: 50 ms/div to 5 s/div at 1 kW only.
    Waveform Acquisition/Display Functions
    Acquisition Modes Normal, averaging, envelope, high resolution
    Record Length
  • 701610:1 kW, 10 kW, 100 kW, 1 MW, 8 MW (Single)
  • 701620:1 kW, 10 kW, 100 kW, 1 MW, 4 MW, 10 MW (Single), 32 MW (Single)
  • Zooming Up to two locations can be set with separate enlargement ratios. (Display: Main, Z1 only, Z2 only, Main & Z1, Main & Z2, Main & Z1 & Z2)
    History Memory Automatically saves acquisition data of up to 16,000 records.
    Display Format The display can be split to one, two, or four windows.
    X-Y Display Two X-Y waveform displays (XY1 and XY2) can be displayed in separate windows.
    Accumulate Permits waveform overlaying (Persistence, Color)
    Analysis Functions
    Search and Zoom Edge, Serial Pattern, Parallel Pattern, Pulse Width, Auto Scroll
    History Search Zones, Parameters
    Cursor Measurement Marker, Horizontal, Vertical, Degree, Vertical History
    Automatic Waveform Parameter Measurement Peak-to-peak, Max, Min, Avg, Rms, Sdev, High, Low, +Oshot, -Oshot, Int1TY, Int2TY, Int1XY, Int2XY, Freq, Period, Rise, Fall, +Width, -Width, Duty, Burst1, Burst2, Pulse, AvgFreq, AvgPeriod, Delay (between channels)
    Waveform Parameters for Statistics Parameters: Listed above
    Statistics: Min, Max, Avg, Cnt, Sdv
    Statistical modes: Normal Statistics, Cycle Statistics, History Statistics
    Math Function Addition, Subtraction, Multiplication, Power Spectrum
    GO/NO-GO Judgment GO/NO-GO judgment based on waveform parameter measurement values or waveform zones
    Screen Image Output
    Built-in Printer (optional) 112 mm paper width
    Screenshot output as hard copy or enlarged and output on multiple pages.
    External Printer (optional) Output to external printer through USB or Ethernet port ESC/P, ESC/P2, LIPS3, PCL5, and BJ commands supported.
    Floppy Drive, Zip R Drive, PC Card, and Network Drive Output formats: PostScript, TIFF, BMP, JPEG, PNG
    ▷ Rear Panel I/O Ports
    Communication Interfaces Serial port (RS232), USB port (optional), USB-PC port(optional), GP-IB port (optional*), Ethernet port(complies with 100BASE-TX and 10BASE-T; optional*)
    * : Choose one from the Ethernet port and GP-IB port options.
    Signal I/O External Trigger Input/External Clock Input, Trigger Output, VGA video signal output, GO/NO-GO judgment I/O, CH1-OUT
    Probe Power Port (optional) Output ports: 4
    Output voltage: ±12 V
    ▶ 일반사양(General Specifications)
    Rated Supply Voltage 100 to 120 VAC/200 to 240 VAC (automatically switches)
    Rated Supply Frequency 50/60 Hz
    Power Consumed 100 VA
    Exterior Dimensions 220(W) X 266(H) X 224(D) mm
    (with printer cover closed; does not include protrusions)
    Weight Approx. 4.5 kg (10.8 lbs; with all options)
    Approx. 3.9 kg (8.6 lbs; without any options)
    Operating Temperature Range 5°C to 40°C
    Operating Conditions Ambient temperature 23 ± 5°C
    Ambient humidity 55 ±10% RH
    Measurements taken based on internal clock after calibration, following warmup period under reference operating conditions.
    ◈ 장비사양 보기
    ▷ Model DL 1640/1640L Download specification(PDF file)
    ** 이 파일은 pdf파일이므로 Acorbat Reader 프로그램을 설치하신 후 보실수 있습니다. **
    ◆ 다운로드(Download) 방법 : 마우스의 오른쪽 키를 누른 후 "다른 이름으로 대상 저장(A).."을
    선택한 다음 저장하신 후 보시면 편리합니다
    출처 : 태평계측기
    글쓴이 : 관리자 원글보기
    메모 :

    '신품장비 > 요고가와' 카테고리의 다른 글

    DL-7440,DL-7480  (0) 2008.02.29
    DL-1620,DL-1640,DL-1640L(4CH)  (0) 2008.02.29
    DL-708E  (0) 2008.02.29
    DL-716  (0) 2008.02.29
    DL-1540C  (0) 2008.02.29