Notice
Recent Posts
Recent Comments
Link
일 | 월 | 화 | 수 | 목 | 금 | 토 |
---|---|---|---|---|---|---|
1 | ||||||
2 | 3 | 4 | 5 | 6 | 7 | 8 |
9 | 10 | 11 | 12 | 13 | 14 | 15 |
16 | 17 | 18 | 19 | 20 | 21 | 22 |
23 | 24 | 25 | 26 | 27 | 28 |
Tags
- Power Supply
- 000 JFW AC Power Analyzer PA-2100 1대 \870
- 000 ez digital current amp tm503a +a6303 1조 \900
- 태평계측기
- watt meter
- 000 jfw ac power analyzer pa-2100 1대 \870
- LCR METER
- 000 화신계기 AC Power Source CVFT1-200H 2대 390
- E3631A
- 000 Escort AC Digital Clamp Meter Hioki 3261 Hioki NEW Attenuator High Power Attenuator HP8498A 1대 \300
- 000 화신계기 ac power source cvft1-200h 2대 390
- 000 화신계기 AC Volt Meter HS-7016 1대 \20
- bird
- 산업용품상가8-306) 구주소:인천광역시 동구 송현동 129 산업용품상가 8동306호 품명 모델 수량 단가가격 maker 부가세별도 금액 입니다 ac current probe fluke80i-600 1대 \50
- 내전압시험기
- 000 audio generator sag-102a 1대 \ 75
- 000 AV Power AC Watt Meter HSW-7013 5대 \35
- 000 HP Attenuator Rotary 50DR-003 3대 \150
- 티스토리챌린지
- 보유계측기는 항상 바뀌니까 날짜 확인 바랍니다 계측기수리 전문 태평계측기 홈페이지 http://cafe.daum.net/tpm8657 휴대폰 010-9135-2888 전화 032-589-8657 070-7539-8657 담당:임연원 이메일 :limyounwon@hanmail.n
- 오블완
- DC Power Supply
- 000 Fluke AC CLAMP METER 72-5090 1대 \16
- 000 fluke ac digital clamp meter hioki 3261 hioki attenuator rotary 50dr-003 3대 \150
- 보유계측기는 항상 바뀌니까 날짜 확인 바랍니다 계측기수리 전문 태평계측기 홈페이지 http://cafe.daum.net/tpm8657 휴대폰 010-9135-2888 전화 032-589-8657 070-7539-8657 담당:임연원 이메일 :limyounwon@hanmail.net 신주소:인천광역시 동구 방축로37번길 30 (송현동
- Power Meter
- 000 TENMA AC DIGITIAL CLAMPMETER ECT-620 \35
- 산업용품상가8-306) 구주소:인천광역시 동구 송현동 129 산업용품상가 8동306호 품명 모델 수량 단가가격 Maker 부가세별도 금액 입니다 AC CURRENT PROBE Fluke80i-600 1대 \50
- spectrum
- Telewave
Archives
- Today
- Total
태평계측기
PS6-60 본문
Regulated DC Power Supplies
PS6-60 |
|
|
Outline |
The PS Series power supplies are DC constant-voltage (CV)??A??i constant-current (CC) power supplies based on the variable switching method??A??i featuring compact size??A??i light weight??A??i excellent reliability and the variable outputs. They have been designed as highly universal stand-alone type models putting emphasis on the ease of operation and safety and equipped with a variety of protection functions. Three capacity types are available including 360W??A??i 720W??A??i and 1080W and 13 kinds of variations are available by combining ranges of 0 to 6 V??A??i 10 V??A??i 20 V??A??i 36 V and 60 V. Several versatile applications are also provided including remote control functions with GP-IB control capability (which is possible when the optional GP-600 is used.) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Features |
●Compact Size, Light Weight, High Efficiency Thanks to the advanced switching method, the PS Series power supplies are both compact and light , with less than half the mass and volume of previous power supply models, resulting in an excellent space factor and high efficiency. ●Digital Display of Voltage and Current Output voltage and current are indicated on 7-segment red LED displays to allow easy checking. ●GP-IB System Compatibility In addition to the output voltage and current control capabilities and status signal outputs, the output on/off, power on/off control and remote/local switches are provided. The GP-IB control is also possible optionally (when the optional GP-600 is combined.) ●Wide Applications Control operations include control by an external voltage or resistance of the output voltage and current. ●Low Noise The temperature-sensitive fan motor reduces the rotation speed when the load is light or the ambient temperature is low to prevent noise. ●Front Air Intake The forced air cooling system intakes air through the front panel and increases the packing density in case the power supply is mounted in a device or rack. The front grill incorporate an air filter to improve dust protection. ●Safety (Fail-Safe Function) For safety, the switching operation is stopped (output off status) and the AC power relay is interrupted while a protection function is operating. ●Output over-voltage protection (OVP) When the output voltage exceeds the OVP setting value, the switching operation (oscillation) is stopped and the output is turned off. ●Output over-current protection (OCP) Increase in the output current to 110% or more of the rated current is detected by a protection circuit, which stops the switching operation and interrupts the AC power relay. ● Over-heat protection (OHP) When the heat sink temperature reaches about 100℃, the switching operation is stopped and the AC power relay is interrupted. ●Input power abnormality protection In case of input over-voltage, input voltage drop or an over-current due to internal abnormality, the switching operation is stopped and the output is turned off. ●Alarm (power abnormality) signal When the output over-current, input over-voltage or input over-current is detected, when the over-heat protection circuit is activated or when the power is switched off, an alarm signal is generated to turn the output off and interrupt the AC power relay. ●Power relay off signal When trouble occurs on the user side, etc., the power relay is interrupted by an external signal. (Rush current protection circuit) The rush current protection circuit is activated at the moment of the power is switched on to reduce the input surge current. ●SPECIFICATIONS
*1: Between 20 Hz and 1 MHz.
|