관리 메뉴

태평계측기

PD18-10A 본문

신품장비/켄우드

PD18-10A

임연원 2006. 2. 17. 13:02
Regulated DC Power Supplies
PD18-10A



 

Outline
The PD-A/AD Series power supplies are DC constant-voltage (CV)??A??Aconstant-current (CC) power supplies with variable output level featuring the use of the phase control method and high reliability. Inheriting the reliability and accuracy of the highly approved PD Series and incorporating a wide variety of protection facilities??A??Athe PD-A/AD Series power supplies have been designed with emphasis on the ease of operation and safety in use as research and experiment power supplies or long aging system power supplies. With 9 combinations of different voltage/current capacity values and the meter indication type and digital indication type models available for each of them??A??Aa total of 18 models offer a wide variation which can be selected according to applications.
Features
High Stability, Large Capacity
A unique phase control method which uses a built-in pre-regulator ensures fast response and efficient high-stability supply of high currents.

Low Ripple, Low Noise
The unique phase control method is combined with a choke-input type smoothing circuit to provide excellent input and load variation rates, low ripple and low noise.

High-Accuracy Voltage and Current Settings
The output voltage as well as the output current can be set using 10-turn potentiometers, enabling smooth, fine setting.

Remote Sensing
This function compensates for the voltage drop at the load terminals which is caused by resistance of leads between the PD-A Series supply output terminals and the load and by output terminal contact resistance.

Remote Control
The output voltage and current can be controlled by means of an external DC voltage or resistance. In addition, it is also possible to remote control the OUTPUT on/OFF by means of a contact switch.

Voltage/Current Limiting
A V/I CHECK switch is provided to allow setting the constant voltage and constant current setting values. The voltage and current values can be set and checked even while the output is on.

Parallel Operation
By connecting the PD-A Series power supplies of the same model in a master-slave configuration, a single master can control all of the slave supplies. This parallel operation makes it possible to increase the output current.

Series Operation
The output voltage can be increased by series connection. A series connection in the master-slave mode of operation is also possible, with which a single master can control all of the slave supplies (provided that the allowable grounding voltage is within ±250 V.)

GP-IB System Compatibility
The voltage and current can be set with high accuracy through GP-IB by connecting the optional GP-610D GP-IB adapter. The OUTPUT on/OFF can also be controlled through the GP-IB if the OP-12 EXT I/O unit (factory option) is added.

GP-IB System Compatibility
The voltage and current can be set with high accuracy through GP-IB by connecting the optional GP-610D GP-IB adapter. The OUTPUT on/OFF can also be controlled through the GP-IB if the OP-12 EXT I/O unit (factory option) is added.

OUTPUT on/OFF
The OUTPUT switch allows you to turn the output voltage on and off electronically. This can also be controlled externally by means of a contact switch.

OVP (Over-Voltage Protection)
The OVP protects the load from excessive voltage by switching the power off instantaneously in cases of operational mistakes or unexpected accidents. The OVP setting voltage can be displayed by pressing the OVP CHECK switch, and the setting can be made using a semi-fixed potentiometer on the front panel. The OVP setting voltage can be set or checked even while the output is on, without interrupting the use of the power supply.

OCP (Over-Current Protection)
The OCP protector circuits detects output current level above about 120% of the rated current and switches the power off.

OHP (Over-Heat Protection)
The OHP protector circuit detects the rise of heat sink temperature at about 100degree C and switches the power off.

OHP (Over-Heat Protection)
The OHP protector circuit detects the rise of heat sink temperature at about 100degree C and switches the power off.

LED Indicators
The green LED lights during constant-voltage operation and the red LED lights during constant-current operation.

Output
The output is supplied from 3 terminals based on the floating method.

SPECIFICATIONS
Model PD18-10A/10AD PD18-20A/20AD PD18-30A/30AD PD36-10A/10AD PD36-20A/20AD PD56-6A/6AD PD56-10A/10AD PD110-3A/3AD PD110-5A/5AD
Output
Output voltage 0 to 18V 0 to 36V 0 to 56V 0 to 110V
Output Current 0 to 10A 0 to 20A 0 to 30A 0 to 10A 0 to 20A 0 to 6A 0 to 10A 0 to 3A 0 to 5A
Model PD18-10A/10AD PD18-20A/20AD PD18-30A/30AD PD36-10A/10AD PD36-20A/20AD PD56-6A/6AD PD56-10A/10AD PD110-3A/3AD PD110-5A/5AD
Voltage regulation characteristics
Line regulation (with respect to ±10% variation in AC) 0.005% 1mV
Load regulation (with respect to change from 0 to 100%) 0.005% 1mV 0.005% 2mV 0.005% 1mV 0.005% 2mV 0.005% 1mV 0.005% 2mV 0.005% 1mV
Ripple/noise (10Hz to 1MHz)(typical) 0.5mVrms 1mVrms
Transient response 50μs 100μs 50μs 100μs 50μs
Remote control resistance/voltage 0 to 10kΩ/0 to 10V
Model PD18-10A/10AD PD18-20A/20AD PD18-30A/30AD PD36-10A/10AD PD36-20A/20AD PD56-6A/6AD PD56-10A/10AD PD110-3A/3AD PD110-5A/5AD
C urrent regulation characteristics
Line regulation (with respect to ±10% variation in AC) 1mA 5mA 1mA 5mA 1mA 3mA 1mA
Load regulation (with respect to change from 0 to 100%) 5mA
Ripple/noise (10Hz to 1MHz)(typical) 3mArms 10mArms 3mArms 10mArms 2mArms 3mArms 1mArms
Remote control resistance/voltage 0 to 10kΩ/0 to 10V
Model PD18-10A/10AD PD18-20A/20AD PD18-30A/30AD PD36-10A/10AD PD36-20A/20AD PD56-6A/6AD PD56-10A/10AD PD110-3A/3AD PD110-5A/5AD
P rotective circuit
Temperature detection Approx. 100°C (power is shut off)
Over-voltage protection 15% to 110% of rated output voltage (power is shut off)
Input fuse rating (AC 100V/200V) 7A/4A 15A/8A 20A/10A 12A/6A 20A/10A 10A/5A 15A/8A 10A/5A 15A/8A
Model PD18-10A/10AD PD18-20A/20AD PD18-30A/30AD PD36-10A/10AD PD36-20A/20AD PD56-6A/6AD PD56-10A/10AD PD110-3A/3AD PD110-5A/5AD
Meter and display
A type Voltmeter (2.5%) F.S. 18V 36V 56V 110V
Ammeter (2.5%)F.S. 10A 20A 30A 10A 20A 6A 10A 3A 5A
AD type Digital voltage display 3-1/2 digits, 19.99V, 199.9V (F.S.) two automatically switched ranges ± (0.1%rdg 1digit) 23°C±5°C, PH80% or less
Digital current display 3 digits or 3-1/2 digits, fixed range ±(0.5% of rdg 1 digit) 23°C±5°C, PH80% or less
19.99A(F.S.) 99.9A(F.S.) 19.99A(F.S.) 99.9A(F.S.) 99.9A(F.S.)
Constant-voltage operation display Green LED lights for CV
Constant-current operation display Red LED lights for CC
Output on display Red LED lights when output is on
Model PD18-10A/10AD PD18-20A/20AD PD18-30A/30AD PD36-10A/10AD PD36-20A/20AD PD56-6A/6AD PD56-10A/10AD PD110-3A/3AD PD110-5A/5AD
A dded functions
Output switch Output switchable on/OFF (Incase of the OFF position, set output voltage is indicated the meter or LED display)
Voltage/current check switch Switch on: indicates the regulated voltage or current on the meter or LED display.
Over-voltage protection preset Switch on: indicates the operating voltage setting of the over-voltage protection circuit.
Remote sensing Possible
Series/Parallel control Master- slave operation
Model PD18-10A/10AD PD18-20A/20AD PD18-30A/30AD PD36-10A/10AD PD36-20A/20AD PD56-6A/6AD PD56-10A/10AD PD110-3A/3AD PD110-5A/5AD
Operating environment
Temperature/humidity for operation 0 to 40°C, 80% or less
Cooling system Forced air (fan)
Output polarity Positive or negative side groundable
Groundable voltage ±250V DC
Model PD18-10A/10AD PD18-20A/20AD PD18-30A/30AD PD36-10A/10AD PD36-20A/20AD PD56-6A/6AD PD56-10A/10AD PD110-3A/3AD PD110-5A/5AD
Power requirements/Others
Voltage 100V/120V/200V/220V/240V AC, 50/60Hz
Power consumption Approx. 0.36kW Approx. 0.62kW Approx. 0.93kW Approx. 0.56kW Approx. 1kW Approx. 0.5kW Approx. 0.8kW Approx. 0.5kW Approx. 0.8kW
  Approx. 0.53kVA Approx. 1kVA Approx. 1.4kVA Approx. 0.83kVA Approx. 1.5kVA Approx. 0.8kVA Approx. 
1.25kVA
Approx. 0.8kVA Approx. 1.25kVA
Case dimensions (W?~H?~D) mm 208?~147?~300 208?~147?~420 208?~147?~457 208?~147?~300 208?~147?~420 208?~147?~300 208?~147?~348 208?~147?~300 208?~147?~348
Maximum dimensions (W?~H?~D) mm 208?~168?~346 208?~168?~483 208?~168?~520 208?~168?~346 208?~168?~483 208?~ 168?~346 208?~168?~394 208?~168?~346 208?~168?~394
(With power input connector mounted) 208?~168?~355 208?~168?~486 208?~168?~523 208?~168?~361 208?~168?~486 208?~168?~361 208?~168?~409 208?~168?~361 208?~168?~409
L1/L/L2 (mm) 23/300/23 28/420/35 28/457/35 23/300/23 28/420/35  23/300/23 23/348/23 23/300/23 23/348/23
Weight Approx. 12kg Approx. 19kg Approx. 24kg Approx. 14kg Approx. 23kg Approx. 14kg Approx. 18kg Approx. 14kg Approx. 18kg

'신품장비 > 켄우드' 카테고리의 다른 글

PA18-3A  (0) 2006.02.17
PAR18-5  (0) 2006.02.17
PDS36-10  (0) 2006.02.17
PR30-3P  (0) 2006.02.17
PR18-5A  (0) 2006.02.17