TONE/PULSE |
|
Type |
Tone/Pulse |
|
|
|
Mode |
Sequence , Random |
|
|
|
TONE |
|
Frequency |
|
|
- Accept Range |
Standard Normal Frequency ±1.7% |
|
- Accuracy |
±0.8Hz (typically 0.5Hz) |
|
- Resolution |
0.1Hz |
|
- QC Limit |
0.01% step |
|
|
|
Level |
|
|
- Range |
0.0~-25.5dBm (0.1㏈ Step) |
|
- Accuracy |
±0.5㏈ @0~-20.0dBm (±0.3㏈@-1~-15dBm, Typically) ±0.8㏈ @-20.1~-25.5dBm |
|
- QC Limit |
0.1㏈ Step |
|
- Twist |
-25.5~25.5㏈ (0.1㏈ Step ) |
|
|
|
Test Speed |
DTMF ON Time ( Minimum 65msec ) DTMF OFF Time ( Minimum 40msec ) |
|
|
|
Tel Line Impedance |
300Ω/600Ω/900Ω/Ext(user define) |
|
|
|
PULSE |
|
Dialing Speed |
6.5~25.0 PPS |
|
- Accuracy |
±0.3PPS |
|
- QC Limit |
0.1PPS Step programmable |
|
|
|
Make-Break Ratio |
20~80% |
|
- Accuracy |
±2% |
|
- QC Limit |
0.1% Step programmable |
|
|
|
Dual Trigger Level |
High trigger level 10~50㎃ (1㎃ Step ) Low trigger level 1~10㎃ (1㎃ Step ) |
|
|
|
Inter Digit Time |
Minimum 150msec |
|
|
|
RING |
|
Mode |
Toggle, Auto Sweep, Continuous |
|
|
|
Frequency |
10~90Hz sine wave (1Hz Step ) |
|
|
|
Level |
0~150Vrms (1Vrms Step ) |
|
|
|
Duration |
0~15sec (1sec Step ) |
|
|
|
Time of Delay Cut OFF |
50msec for the puncture test |
|
|
|
FLASH TIME TEST |
|
Range |
50msec~3000msec |
|
|
|
QC Limit |
1msec Step |
|
|
|
RECEIVING TEST |
|
Frequency |
200Hz~3400Hz(1Hz Step programmable) |
|
|
|
Single Tone |
400Hz sine wave, normal continuous, change (new voice) |
|
|
|
Duration |
0~15sec (0.1sec Step programmable) |
|
|
|
Level |
-3~-54dBm (1㏈ Step programmable) |
|
|
|
Dial Tone |
350Hz + 440Hz ,continuous |
|
|
|
Ring Back Tone |
440Hz + 480Hz ,1sec ON, 2sec OFF |
|
|
|
Busy Tone |
480Hz + 620Hz ,0.5sec ON, 0.5sec OFF |
|
|
|
Congest Tone |
480Hz + 620Hz ,0.3sec ON, 0.2sec OFF |
|
|
|
FEED CURRENT & ARTFICIAL LINE |
|
Feed Voltage |
24~75V adjusted by VR |
|
|
|
Feed Resistance |
2 × 200Ω, 120㎃ current max @48V |
|
|
|
Loop Current Adjust |
15~120㎃ (@48V, Short Load) |
|
|
|
Artificial Line |
0~7.5km (0.5km Step programmable) @140Ω × 2/km line Simulation |
|
|
|
Current Meter |
150㎃ FS |
|
|
|
PAY TEST |
|
Coin Test |
Duration Forward = 1~60sec (1sec Step ) Reverse = 200~500msec (1msec Step ) |
|
|
|
Metering Pulse |
Freq. : 11kHz~19kHz Level : 0~550㎷ Duration ON : 40~500msec Duration OFF : 50msec~30sec |
|
|
|
INTERFACE |
|
Digital I/O |
16bit TTL Level (user programmable I/O via RS232C) |
|
|
|
RS 232C |
9600BPS |
|
|
|
OTHERS |
|
Power Requirements |
115/230VAC (Auto Selection), 50/60Hz |
|
|
|
Dimensions |
130(H) ×430(W) × 310(D)mm |
|
|
|
Weight |
Approx. 8.7㎏ |
|
|
|
Standard Accessories |
Power Cable, Telephone Cable, Operating Manual, Fuse |
|
|
|
Option Accessories |
Foot Switch (Remote Sending) RS-232C Cable |
|
|
|
Options |
Caller ID (Bellcore, BT, CCA, DTMF) ; Korean/English |
|