TDS 1000 Series
임연원
2006. 1. 13. 09:48

TDS 1000 시리즈(2CH) : 모델 TDS 1002(60MHz), TDS 1012(100MHz) |
▷ 특 징 (Features) | |
|
|
▷ 응 용 (Applications) | |
|
▷ TDS1000 Series Specifications | ||
모 델 | TDS1002 | TDS1012 |
Display (1/4 VGA LCD) |
Mono | Mono |
Bandwidth*1 | 60 MHz | 100 MHz |
Channels | 2 | 2 |
External Trigger Input |
Yes on all models | |
Sample Rate on each channel |
1.0 GS/s | 1.0 GS/s |
Record Length | 2.5 K points on all models | |
Vertical Resolution | 8-bits | |
Vertical Sensitivity | 2 mV to 5 V/div on all models with calibrated fine adjustment | |
DC Vertical Accuracy |
±3% on all models | |
Vertical Zoom | Vertically expand or compress a live or stopped waveform | |
Max Input Voltage | 300 VRMS
CAT II; derated at 20 dB/decade above 100 kHz to
13 Vp-p AC at 3 MHz and above |
|
Position Range | 2 mV to
200 mV/div ±2 V >200 mV to 5 V/div ±50 V |
|
BW Limit | 20 MHz for all models | |
Input Coupling | AC, DC, GND on all models | |
Input Impedance | 1 MOhm in parallel with 20 pF | |
Time
Base Range |
5 ns to 50 sec/div | 5 ns to 50 sec/div |
Time Base Accuracy |
50 ppm | |
Horizontal Zoom | Horizontally expand or compress a live or stopped waveform | |
Trigger Modes | Auto, Normal, Single Sequence. | |
Trigger Types |
|
|
Trigger Source | CH1, CH2, Ext, Ext/5, AC Line. | |
Trigger View | Displays trigger signal while trigger view button is depressed. | |
Trigger Signal Frequency Readout | Provides a frequency readout of the trigger source. | |
Cursors |
|
|
Automatic Waveform Measurements | Period, Frequency, +Width, -Width, Rise-time, Fall-time, Max, Min, Peak-to-Peak, Mean, Cycle RMS. | |
Autoset Menu | Single-button, automatic setup of all channels for vertical, horizontal and trigger systems, with undo autoset. | |
Dimensions | 323.8mm(W) X 151.4mm(H) X 124.5mm(D) | |
Weight | 2.0kg(Instrument only), 2.2kg(with accessories) | |
*1 Bandwidth is 20 MHz at 2 mV/div, all models. |
▷ TDS2CMA : Communications Extension Module(Options) | |
Printer Port |
|
GPIB Port | Programmability(IEEE std. 488-1987), Full talk/listen modes. Control of all modes, settings and measurements. Includes WaveStarTM software for oscilloscopes, 30-day product demo. |
RS-232 Port | Programmability - Full talk/listen modes. Control of all modes, settings and measurements. Baud rate up to 19,200. 9-Pin, DTE. |
▷ 선택사양(Options) | |
TDS2CMA | Communications Extension
Module (Includes user and programmer manuals. Does not include I/O cable). |
AD007 | LAN/WAN GPIB converter. |
AC220 | Soft case for carrying instrument. |
HCTDS32 | Hard plastic case for carrying instrument (requires AC220). |
RM2000 | Rackmount kit. |
071-1076-00 | Service Manual (TDS1000 and TDS2000 Series Digital Storage Oscilloscopes) - English only |
071-1075-00 | Programmer Manual (TDS200, TDS1000 and TDS2000 Series Digital Storage Oscilloscopes) - English only |
WSTRO | WaveStarTM Software for Oscilloscopes - Windows 95/98/NT 4.0 application for waveform capture, analysis, documentation and control from your PC. |
TNGTDS01 | Operator Training Kit - Extensive instructions and step-by-step lab exercises provide education about the operation of the TDS1000 and TDS2000 Series oscilloscopes. Kit includes a self-paced CD-ROM-based manual and signal source board. Optional hard copy manual is available for order separately. |
▷ 선택사양-프루브(Options-Probes) | |
P2200 | 10X - 1X switchable passive probe (200 MHz when 10X is selected). |
P6015A | 1000X high voltage passive probe (75 MHz). |
P5100 | 100X high voltage passive probe (250 MHz). |
P5200 | High voltage active differential probe (25 MHz). |
P6021 | 60 MHz AC current probe. |
P6022 | 120 MHz AC current probe. |
A621 | 2000 A AC current probe/BNC. |
A622 | 100 A AC/DC current probe/BNC. |
AM503S | AC/DC current probe system. |
◈ 카탈로그 사양 보기 |
▷ Model TDS1002/TDS1012 Download Datasheet(PDF
file-영문판) ▷ Model TDS1002/TDS1012 Download Datasheet(PDF file-한글판) |
|